首都医科大学学报 ›› 1996, Vol. 17 ›› Issue (1): 17-19.

• 论著 • 上一篇    下一篇

用色质联用方法对蓄电池盒生产车间硫化烟气成分的分析

郭爱民1, 张明程1, 张淑华1, 尹娜1, 王晖1, 李华民2   

  1. 1. 首都医科大学卫生化学教研室;2. 北京师范大学分析测试中心
  • 收稿日期:1995-03-11 修回日期:1900-01-01 出版日期:1996-01-15 发布日期:1996-01-15

GC/MS Analysis of Vulcanizing Fume

Guo Aimin1, Zhang Mingcheng1, Zhang Shuhua1, Yin Na1, Wang Hui1, Li Huaming2   

  1. Department of Sanitory Chemistry, Capital University of Medical Sciences
  • Received:1995-03-11 Revised:1900-01-01 Online:1996-01-15 Published:1996-01-15

摘要: 用气相色谱-质谱(简称色质联用,GC/MS)方法分析了蓄电池盒生产车间硫化烟气的成份,从中分析出芘及荧蒽2个多环芳烃化合物,为硫化烟气的致突变、致癌作用提供了证据。

关键词: 色谱-质谱, 硫化烟气, 多环芳烃

Abstract: The qualititive analysis of vulcanizing fume in the workshop of boxes of storage battery by GC/MS was reported.Two PAH compounds in vulcanizing fume were detected.This study offers testimony on acting mutagenicity and cancer for vulcarizing fume.

Key words: GC/MS, vulcanizing fume, PAH