摘要: 高效液相色谱法测定血浆中阿魏酸的含量.使用岛津LC-4A型高效液相色谱仪.YWG-G18H37填充柱(25cm×4.6mmi.d).以乙二胺、甲酸调至pH3~4的60%甲醇混合液作流动相.紫外312nm检测,用内标法定量,内标物为肉桂酸.测定结果,回收率平均值为94.25%,相对标准偏差2.15%(8次测定).标准曲线呈线性关系.本法简便快速、重现性好.

关键词: 阿魏酸, 肉桂酸, 高效液相色谱

Abstract: This paper is about the determination of the plasma ferulic acid concentration by high performance liquid chromatograph (HPLC). A Shimadzu liquid chromatograph LC-4A with a column (25cm×4.6mm) of YWG-C18H37(C18 chemical bonded stationary phase) was used.60% methanol containing ethylendiamine and methanoic acid to a mixing liquid with pH value of 3~4 was chosen as the mobile phase.The detection was at 254nm.The quantity of ferulic acid was determined by the internal standard method with cinnamic acid as a reference.The results showed that the standard deviation was 2.15%(eight determinations),the rate of recovery was 94.25% and the standard curve was well linear. The proposed method is simple,rapid and reproducible.