首都医科大学学报 ›› 2008, Vol. 29 ›› Issue (4): 487-489.

• 临床研究 • 上一篇    下一篇

实时三维超声心动图评价冠心病患者左心功能

高敬, 华琦, 王彩荣, 李晓辉, 高承梅   

  1. 首都医科大学宣武医院心脏科
  • 收稿日期:2008-02-16 修回日期:1900-01-01 出版日期:2008-08-24 发布日期:2008-08-24
  • 通讯作者: 华琦

Evaluation of Left Ventricular Function of Patients with Coronary Heart Disease by Using Real Time Three Dimensional Echocardiography

Gao Jing, Hua Qi, Wang Cairong, Li Xiaohui, Gao Chengmei   

  1. Department of Cardiology, Xuanwu Hospital, Capital Medicial University
  • Received:2008-02-16 Revised:1900-01-01 Online:2008-08-24 Published:2008-08-24

摘要: 目的 应用实时三维超声心动图技术评价冠心病患者左心功能.方法 分别对80例冠心病患者进行二维超声心动图及三维超声心动图检查.测量左室舒张末期容积(end diastolic volume,EDV)、收缩末期容积(end systolic volume,ESV)和左室射血分数(left ventricularej ection fraction,LVEF).采用配对t检验相关性分析.结果 70例患者完成检查,二维超声心动图与实时三维超声心动图测量的左室舒张末容积、收缩末容积、射血分数相关系数分别为:EDV,r=0.875;ESV,r=0.912;EF,r=0.905.二维超声心动图与实时三维超声心动图比较,低估左室收缩末及舒张末容积,高估左室射血分数.结论 实时三维超声心动图技术能够比较准确评价冠心病患者左心功能.

关键词: 实时三维超声心动图, 冠心病, 左心功能

Abstract: Objective The effects of coronary heart disease on left ventricular(LV) function have been studied by various echocardiographic techniques(M-mode,2D echocardiography).These studies are hampered by a low accuracy of measurements because of geometric assumptions regarding LV shape.Real time three-dimensional echocardiography(RT-3DE) can overcome this limitation.Methods We detected 80 patients with coronary heart disease by 2D and RT-3D echocardiography.Each one was tested the feasibility of RT-3DE assessment of LV function.Conventional biplane Simpson rule(BSR) for LV function analysis was used as a reference.Paired t test was used for analysis of differences within the variations.Correlation analysis was performed for RT-3DE and 2DE measurements.Results All the patients were studied and in 70 of 80(87.5%) RT-3DE datasets were acquired.In 10 patients,the dataset was of insufficient quality and excluded from analysis.Correlation between BSR and RT-3DE for calculation of end-diastolic volume(EDV,r=0.875),end systolic volume(ESV,r=0.912) and for ejection fraction(EF,r=0.905) was moderate.2DE methods underestimated end diastolic and end-systolic volume,while overestimating ejection fraction.Conclusion RT-3DE is feasible for image acquisition during coronary heart disease,which opens the possibility for accurate and reproducible measurement of LV function.This may improve the assessment of the acute effect of coronary heart disease on LV performance,and guide therapeutic strategies.

Key words: real time three-dimensional echocardiography, coronary heart disease, left ventricular function

中图分类号: