Recording of Rat Descending Spinal Field Potentials Using Insulated Pin Electrode through Intervertebral Puncture

Yang Jianfeng, Lu Guowei   

  1. Department of Neurobiology, Capital University of Medical Sciences
  • Received:1994-11-11 Revised:1900-01-01 Online:1996-01-15 Published:1996-01-15

Abstract: By means of the loss-of-resistance guidance method, insulated pin-electrodes were inserted into the epidural space through intervertebral puncture for segmental spinal cord stimulation and recording.Typical spinal field potential could be recorded from the epidural space of the lumbar enlargement.which was similar to the field potential recorded from the dorsai surface of the spinal cord directly by silver ball electrode.The result indicates that the method for recording spinal cord field potential by insulated pin electrode through intervertebral puncture can not only be applied to man and big animals but also to small animals like rat.

Key words: insulation pin electrode, descending evoked potential, rat