Journal of Capital Medical University ›› 2004, Vol. 25 ›› Issue (4): 525-527.

• 论著·临床研究 • Previous Articles     Next Articles

Hysteroscopic Management of Difficult Removal IUD

Cheng Jiumei, Xia Enlan, Duan Hua, Huang Xiaowu, Zheng Jie, Yu Dan   

  1. Hysteroscopic Center, Beijing Fuxing Hospital, Affiliate of Capital University of Medical Sciences
  • Received:2003-11-07 Revised:1900-01-01 Online:2004-10-15 Published:2004-10-15

Abstract: The aim was to evaluate the safety and efficacy of difficult removal IUD by hysteroscopy and the necessary of B-ultrasound and/or laparoscopic monitoring. Altogether 55 cases transferred from other hospitals because of failing to remove IUD were analysised from Jan 1998 to June 2003. All cases operation were monitored by B-ultrasound, 4 of whom combined laparoscopic monitoring. 53 cases were removed by hysteroscopy, 1 IUD penetrated into pelvic cavity was removed by laparoscopy, 1 case selected trans-abdominal hysterectomy and bilateral salpingo-oophorectomy because of bilateral ovary solid cyst, 2 perforation occurred because of intrauterine adhesion. Difficult removal IUD by hysteroscopy is a safe and effective technique and it is necessary to combine with monitoring of B-ultrasound and laparoscopy.

Key words: hysteroscopy, IUD, B-ultrasound, laparoscopy

CLC Number: